CAS CL3500 combine weighing goods with label printing. The video shows how to prepare a label roll, configure the network connection, and set data exchange parameters with Torgsoft. The IP address and other network details must match your local network settings.
Configuring the scales and label
After connecting the scales, configure the label template and the encoding method for weighed goods. Transfer the required products to the scales, print a test label, and check that the barcode, weight, price, and total are read correctly. The procedure may differ for other scale models.
Video contents
- 00:00 — Introduction
- 00:38 — Assembling CAS CL3500 scales
- 02:48 — Installing consumables
- 05:38 — Turning on CAS CL3500 scales and Dhcp mode
- 07:05 — Turning off Dhcp mode
- 08:30 — Setting a static IP address
- 10:48 — Checking (pinging) the IP address
- 13:20 — Choosing a barcode type
- 15:30 — Configuring the EAN13 barcode structure
- 19:00 — Configuring CAS CL3500 scales on a computer
- 23:10 — Configuring CAS CL3500 scales in the Torgsoft accounting program
- 24:45 — Example of creating a weighed product
- 29:25 — Editing the barcode of a weighed product
- 34:00 — Importing a product into the program for working with scales
- 35:50 — Importing a product into the scales
- 36:35 — Selling a product
- 38:40 — Configuring the label template
- 48:15 — Uploading the label template to the scales
- 49:45 — Selecting the created label template on the scales
Go back to the previous step